Table 3.3 Command parameter setting example for acquiring peripheral data only
 IREG 
 setting value 
 contents 
 IREG0 
 00H 
 Date, cartridge code, area code, terminal status, SMEM, 
Reset Do not return button mode data
 IREG1 
 Application specifications 
(excluding PEN bit
)
 Port 2 mode (P2MD1, P2MD0) = According to application specifications 
Port 1 mode (P1MD1, P1MD0) = According to application specifications
Peripheral data enable (PEN) = 1B Return peripheral data
Acquisition time Optimization (OPE) = Depends on application specifications
 IREG2 
 F0H 
 Unconditionally set to F0H 