Title | Function | Function Name [SR] | No |
Specify the time from 〈PAUSE〉 to 〈STANDBY〉 transition.
Transition to 〈STANDBY〉 state when standby time elapses in 〈PAUSE〉 state.
setting value | description |
|---|---|
0000H | 180 seconds (3 minutes) …… Initial value |
003CH-0384H | Transition time (in seconds) …… 60-900 seconds ( 1 to 15 minutes) |
FFFFH | Do not change settings (CDC_PARA_NOCHG) |
(4) ECC count
∙ Specify the number of ECC processing (PQ correction once) for CD-ROM decoding.
setting value | description |
|---|---|
00H | ECC is processed only once in real time …… Initial value |
01H to 05H | Maximum number of repetitions when there is an error after ECC processing (total 2 to 6 times) |
80H | No ECC processing |
FFH | Do not change settings |
(A) Applies to Mode1 or Form1 sectors.
(B) When bit2 = 1 of initialization flag (Mode2 subheader is not recognized), Mode2 ECC processing is not performed.