Return to previous page Return to menu Go to next page

[Register and refer to interrupt handling routine]

  Title  
Data specifications
  Data  
Vector number constant
  Data name  
None
No
3

The constants that can be set for the vector number are shown below. The SCU constant name can only be set on the master SH2.
∙ CPU constant names can be set on the master and slave SH2.

 Interrupt classification 
 Constant name 
 Description 
SCU
INT_SCU_ABUS
A-Bus
 INT_SCU_SPR 
 End sprite drawing 
 INT_SCU_DMAI 
 DMA illegal 
 INT_SCU_DMA0 
 Level 0-DMA 
 INT_SCU_DMA1 
 Level 1-DMA 
 INT_SCU_DMA2 
 Level 2-DMA 
INT_SCU_PAD
PAD
 INT_SCU_SYS 
 System Manager 
 INT_SCU_SND 
 Sound Request 
 INT_SCU_DSP 
 End DSP 
 INT_SCU_TIM1 
 Timer-1 
 INT_SCU_TIM0 
 Timer-0 
 INT_SCU_HBLK_IN 
 H-blank-IN 
 INT_SCU_VBLK_OUT 
 V-Blank-OUT 
 INT_SCU_VBLK_IN 
 V-Blank-IN 
 CPU 
 INT_CPU_DIVU 
 Divisor 
 INT_CPU_DMAC0 
 DMAC channel 0 
 INT_CPU_DMAC1 
 DMAC channel 1 
 INT_CPU_WDT 
 WDT interval 
 INT_CPU_BSC 
 BSC compare match 
 INT_CPU_SCI_ERI 
 SCI reception error 
 INT_CPU_SCI_RXI 
 SCI received data full 
 INT_CPU_SCI_TXI 
 SCI receive data empty 
 INT_CPU_SCI_TEI 
 SCI transmission end 
 INT_CPU_FRT_ICI 
 FRT input capture 
 INT_CPU_FRT_OCI 
 FRT output compare 
 INT_CPU_FRT_OVI 
 FRT overflow 


Return to previous page Return to menu Go to next page