write once system 3.Troubleshooting
This section describes what to do if an error message is displayed.
Error regarding image file
- If the error message introduced in this section appears, there is a problem with the CD image. Please check if the .dsk or .emu file and .toc file are in the same directory and were created correctly by the virtual CD system. If the error still occurs, please create the CD image again.
●Error regarding image file format
- The following error message means that the CD image you are trying to record is in an invalid format.
- Bad data form
- unknown data form in line
- Error Data Length
- The following error message indicates that the mode of the CD-ROM being created is invalid, or that the CD image is in a format that is not supported by segacdw.
-
●Error regarding ISRC length
- There is a problem with the length of the ISRC stored within the image on the CD. Examine the original data and regenerate the image.
- ISRC length error in line
●Cue sheet error
- If you see an error message like the one below, there is a problem with the cue sheet. Please recreate the .dsk and .toc files using the virtual CD system.
- Cue Sheet intermediate conversion failed
- Cue Sheet parsing failed
- Cue sheet conversion failed
- Cue sheet size error
- Cue sheet too large
- Empty cue sheet
- No track definitions in cue sheet
- Can't find lead-out in cue sheet
- Nocore for cue sheet
- Also, the following error indicates that either the cue sheet has not been generated or there is no file containing the cue sheet in the same directory as the image file.
-
Errors caused by the relationship between the host machine and CD-R recording device
●Errors that occur when transferring CD images
- The following error message means that the I/O speed of the host's hard disk cannot keep up with the writing speed of the CD-R writer. Adjust the CD-R writing speed using command options.
-
●Errors related to CD-R recording device settings
- The following error message occurs when you specify an invalid value for write speed. Please specify the correct write speed using option -s.
-
- The following error message will appear if the firmware version of the CDR100 is old and it is not possible to create a CD for SEGA Saturn. Please update the CDR100 firmware to the correct version.
- Firmware upgrade of CD recorder is needed to use this software.
●Error returned by CD-R recording device
- The following error is returned by the CD-R recording device.
- Unknown sense key
- Unknown additional sense code
- Field Replaceable Unit failed
- Number of Errors
- Error Number [%d] at Logical Block Address
- No Additional Sense
- Caddy Out
- Drive Not Ready
- Communication failure
- Track Following Error
- Unrecovered Read Error
- Positioning error
- Recovered Read Data With Retries
- Recovered Read With ECC Correction
- Parameter List Length Error
- Invalid Command
- Invalid Block Address
- Illegal Field in Command Descriptor
- Invalid LUN
- Invalid Field Parameter List
- Medium Changed
- Power-on Reset or Bus Reset Occurred
- Command Sequence Error
- Medium Format Corrupted
- Write Data Error with CU
- Monitor Atip Error
- Invalid Bits in Identify Message
- Diagnostic failure
- Power-On or Self Test Failure
- Internal Controller Error
- SCSI Parity Error
- Write Operation in Progress
- Medium(Caddy) Load or Eject Failed
- Unable to Read TOC, PMA or Subcode
- Operator Medium Removal Request
- End Of User Area encountered on this Track
- Illegal Mode for this Track
- Illegal Track
- Command Currently Not Vailed
- Medium Removal Is Prevented
- Stopped on Non-data block
- Invalid Start Address
- Attempt to cross track-boundary
- Illegal Medium
- Application Code Conflict
- Illegal block-size for command
- Block-size Conflict
- Request for Fixation Failed
- End Of Medium Reached
- Illegal Track Number
- Data Track Length Error
- Buffer Under Run
- Illegal Track Mode
- Optimum Power Calibration Error
- Calibration Area Almost Full
- Current Program Area Empty
- No EFM at search address
- Link Area Encountered
- Calibration Area Full
- Dummy blocks added
- Block size format conflict
- Current Command Aborted
- BARCODE READING ERROR
- Recovery Needed
- Can't recover from track
- Can't Recover from Program Memory Area
- Can't Recover from Lead-in Area
- Can't Recover from Lead-out Area
- Laser Current Over
▲ Back | ■